What Are You Looking For?
RCH-200E1JA 200 RT Liquid-Suspended Variable-Frequency Centrifugal Chiller
Product introduction
The RCH-200E1JA chiller has a cooling capacity of 705 kW (200 RT) and a standard-condition chilled-water outlet temperature of 7°C. The unit adopts two liquid-suspended variable-frequency centrifugal compressors, a falling-film / flooded evaporator, and a shell-and-tube condenser. The COP is 6.32 and the IPLV is 8.86. The power supply is 380 V, 3-phase, 50 Hz; the starting current is 2 A, the rated current is 171 A, and the maximum current is 197 A. The water-side design pressure is 1.0 MPa. Both the evaporator and condenser water connections are DN150. The overall dimensions are 4185 × 1810 × 1980 mm, and the operating weight is 4050 kg. The parameters are based on the standard conditions of GB/T 18430.1-2024, and the energy-efficiency evaluation is based on GB 19577-2024.
Product Description
RCH-200E1JA 200 RT Liquid-Suspended Variable-Frequency Centrifugal Chiller
The RCH-200E1JA is a 200 RT (705 kW) liquid-suspended variable-frequency centrifugal chiller. It uses two liquid-suspended variable-frequency centrifugal compressors and achieves a COP of 6.32 and an IPLV of 8.86 under standard conditions. It is suitable for centralized cooling applications that require part-load efficiency and operating modulation.

Key Advantages:
Zero Friction, Oil-Free & High Efficiency
15% Minimum Load, High Efficiency Across All Conditions
100% Precision, Software Synergy
Production Parameters
| Parameter | Unit | Specification |
| Performance Parameters | ||
| Cooling Capacity | kW | 705 |
| Cooling Capacity | RT | 200 |
| Chilled Water Outlet Temperature | °C | 7 |
| Input Power | kW | 111.5 |
| Power Supply Capacity | kW | 134 |
| COP | kW/kW | 6.32 |
| IPLV | – | 8.86 |
| Electrical Parameters | ||
| Power Supply | – | 380 V, 3-phase, 50 Hz |
| Starting Current | A | 2 |
| Rated Current | A | 171 |
| Maximum Current | A | 197 |
| Compressor | ||
| Type | – | Liquid-suspended, variable-frequency centrifugal compressor |
| Quantity | – | 2 |
| Evaporator | ||
| Type | – | Falling-film / flooded type |
| Water Flow Rate | m³/h | 121 |
| Pressure | kPa | 55 |
| Water Connection Size | DN | DN 150 |
| Condenser | ||
| Type | – | Shell-and-tube type |
| Water Flow Rate | m³/h | 152 |
| Pressure | kPa | 62 |
| Water Connection Size | DN | DN 150 |
1.200 RT-Class Cooling Capacity, 705 kW Under Standard Conditions
Standard-condition chilled-water outlet temperature 7°C, meeting 200 RT-class centralized cooling selection requirements.
2.Dual Liquid-Suspended Variable-Frequency Centrifugal Compressors
Equipped with 2 liquid-suspended, variable-frequency centrifugal compressors, supporting variable-frequency operation and modulation, with a starting current of 2 A.
3.High-Efficiency Parameters
Standard-condition COP 6.32 kW/kW and IPLV 8.86, with focus on full-load and part-load efficiency.
4.Falling-Film / Flooded Evaporator + Shell-and-Tube Condenser
Evaporator water flow rate 121 m³/h, pressure drop 55 kPa; condenser water flow rate 152 m³/h, pressure drop 62 kPa; both water connections are DN150.
5.Compact Dimensions for Project Layout
Overall dimensions 4185 × 1810 × 1980 mm; shipping weight 3640 kg; operating weight 4050 kg.
6.Standards Compliance and Pressure Customization Note
Standard-condition parameters are based on GB/T 18430.1-2024; energy-efficiency evaluation is based on GB 19577-2024. Water-side design pressure is 1.0 MPa; requirements exceeding this pressure can be specified at the time of ordering.
The RCH-200E1JA is suitable for centralized air-conditioning or process cooling applications requiring 200 RT-class cooling capacity, such as commercial complexes, office buildings, hotels, hospitals, and industrial plants. Actual selection must be checked against project cooling load, chilled-water/cooling-water temperatures, flow rates, pressure drops, installation space, transportation conditions, and local energy-efficiency requirements.
Q1: What is the cooling capacity of the RCH-200E1JA?
A: The standard-condition cooling capacity is 705 kW, corresponding to 200 RT.
Q2: What are the standard conditions?
A: According to GB/T 18430.1-2024, the chilled-water outlet temperature is 7°C, the cooling-water inlet temperature is 30°C, and the chilled-water and cooling-water flow rates are calculated using the coefficients stated in this document.
Q3: What is the water-side design pressure? What if it is exceeded?
A: The water-side design pressure of the evaporator and condenser is 1.0 MPa. If the project operating pressure exceeds 1.0 MPa, this must be specified when placing the order.
Q4: Can the parameters be used directly for final selection?
A: The parameters on this page are standard-condition parameters. Final selection must be confirmed based on project conditions, flow rates, pressure drops, installation, and transportation conditions. Product parameters may be revised due to updates.
--------------占位---------------